EAPSD: Received Ring UP Flush FDB PDU
ExtremeWare Error Message Decoder 899
EAPSD: Received Ring UP Flush FDB PDU
EAPS: EAPSD eaps2a - Received PDU RingUp-FlushFdb-Pdu , [MAC=00:01:30:3b:27:00
Software Version
ExtremeWare 7.2 and later
Hardware Version
All “i” and “e” series
Explanation
This message indicates that the switch is a transit node and the master node has detected an EAPS ring
up. The master node sends a FlushFDB PDU when it detects that the ring is up. All the transit nodes
receive and process the PDU.
Action
Verify the EAPS ring and check whether any port is up.