Invalid Time Values
ExtremeWare Error Message Decoder 619
Invalid Time Values
<WARN:STP> decode_bpdu, received time values out of range "max age" "hello time"
"forward delay"
Software Version
ExtremeWare 6.2.2 or later
Hardware Version
All
Explanation
This message indicates that there are invalid STP timer values in the received BPDU.
Action
1 Capture the incoming STP BPDU and analyze the fields.
2 Check the STP timer configuration of the neighbor switches.
3 If the values are out of range, then correct the values.