Extreme Networks ExtremeWare Version 7.8 Spécifications Page 358

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 978
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 357
358 ExtremeWare Error Message Decoder
Error Messages
Error Reading Register
ERROR: Slot 1 port xx register 8a not ready after select
Software Version
ExtremeWare 6.2 and later
Hardware Version
BlackDiamond, Summit “i” series
Explanation
Timeout occurred while the ASIC tried to read a register on slot 1 on port xx. May be the card is not
active.
The switch will take the action configured using
sys-health-check. If you have configured
sys-health-check to shut down the card, the card is set to non-operational.
Action
Run diagnostics to get details on the hardware. If the problem persists, contact Technical Support.
Vue de la page 357
1 2 ... 353 354 355 356 357 358 359 360 361 362 363 ... 977 978

Commentaires sur ces manuels

Pas de commentaire