Extreme Networks ExtremeWare Version 7.8 Spécifications Page 357

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 978
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 356
Error Reading Register
ExtremeWare Error Message Decoder 357
Error Reading Register
ERROR: tsunamiReadReg: Slot 1 port xx register d not ready after select
Software Version
ExtremeWare 6.2 and later.
Hardware Version
BlackDiamond, Summit “i” series
Explanation
Error occurred while Tsunami ASIC tried to read register d of port XX found on slot 1.
The switch will take the action configured using sys-health-check. If you have configured
sys-health-check to shut down the card, the card is set to non-operational.
Action
Run diagnostics to get details on the hardware. Contact Technical Support, if required.