Vue de la page 103
104 ExtremeWare Error Message Decoder
Critical Messages
Register Failed
<CRIT:PORT> RR - readRRRegister failed - RR NOT READY port = 18
Software Version
ExtremeWare 4.x and 6.x
Hardware Version
BlackDiamond Summit chipset products
Explanation
This message indicates that the register on the I/O module (in the case of BlackDiamond) or on the port
(in the case of Summit) is not ready.
Action
This could be a hardware problem. Run diagnostics. If the diagnostic results indicate bad hardware,
RMA the I/O module or Summit.
If diagnostic does not indicate bad hardware, contact Technical Support to troubleshoot the problem.