66 Advanced System Diagnostics and Troubleshooting Guide
Diagnostics
Interpreting Memory Scanning Results
If single-bit permanent errors are detected on an “i” series switch during the memory scanning process,
these errors will be mapped out of the general memory map with only a minimal loss to the total
available memory on the system.
Example show diagnostics messages for memory scanning:
------------------------------------------------------------------------
Diagnostic Test Result run on Thu May 23 14:24:44 2005
------------------------------------------------------------------------
Slot : B
------------------------------------------------------------------------
CPU System | Passed
------------------------------------------------------------------------
Registers Test | Passed
------------------------------------------------------------------------
Memory Test
Packet memory test Passed
NOTICE: Packet memory test found 2 error(s) that
have been successfully remapped
| Passed
------------------------------------------------------------------------
System Test Passed
------------------------------------------------------------------------
------------------------------------------------------------------------
Packet memory defect info for card MSM-B
------------------------------------------------------------------------
Num of defects = 2, num of recoverable defects = 2
Defect information:
Defect entry 1
recoverable: Yes
mem ID = 4
bit position = 4
address = 0x2d2
Defect entry 2
recoverable: Yes
mem ID = 0
bit position = 8
address = 0x8ca0
------------------------------------------------------------------------