Extreme Networks WM-4T1i Spécifications Page 35

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 306
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 34
Extreme Networks Consolidated Hardware Guide 1-9
GBIC Type and Hardware/Software Support
.
Measure cable plant losses with a 1550 nm light source and verify this to be within
budget. When calculating the maximum distance attainable using optical cable with a
specified loss per kilometer (for example 0.25 dB/km), Extreme Networks recommends
that 3 dB of the total budget be reserved for losses induced by cable splices/connectors
and operating margin. Thus, 18 dB remains available for cable induced attenuation.
A minimum attenuation of 3 dB is required to prevent saturation of the receiver.
Optical input power maximum -3 dBm
Operating wavelength 1285 nm 1343 nm
Table 1-7: 1000BASE-ZX Specifications
Parameter Minimum Typical Maximum
Transceiver
Optical output power -4 dBm -3 dBm -1 dBm
Center wavelength 1540 nm 1550 nm 1570 nm
Receiver
Optical input power sensitivity -23.5 dBm
Optical input power maximum -1 dBm
Operating wavelength 1540 nm 1550 nm 1570 nm
Table 1-8: 1000BASE-ZX Rev 03 Specifications
Parameter Minimum Typical Maximum
Transceiver
Optical output power -2 dBm 0 dBm 2 dBm
Center wavelength 1540 nm 1550 nm 1570 nm
Receiver
Optical input power sensitivity -23 dBm
Optical input power maximum -1 dBm
Operating wavelength 1540 nm 1550 nm 1570 nm
Table 1-6: 1000BASE-LX Specifications (continued)
Parameter Minimum Typical Maximum