Extreme Networks Summit X350-48t Spécifications Page 89

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 110
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 88
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.4 Release Notes
89
PD4-1602297969,
PD4-1517702664
When a Summit x480 switch is connected to a third party switch with H-VPLS peers, and
the link is disabled/enabled between the switches, the LDP peers flap for an extended
period of time with keep-alive timer expired errors.
BlackDiamond 8800 Series Switch
PD4-1633773021 There is a potential for a smbus_xfer:1 smbus_wait_rdy error with frequent SSH,
and telnet management login/logout sessions.
BlackDiamond 10800 Series Switch
PD4-1641608965,
PD4-1108500108
On a BlackDiamond 10800 switch with dual MSMs and a G20X module, CLEAR-Flow
delta rules may be triggered on the backup MSM when not needed.
PD4-1586364405,
PD4-1566158665
On a BlackDiamond 10800 series switch, an MSM failover results in too many SNMP
traps (extremePortMauChangeTrap) being sent.
BlackDiamond 20800 Series Switch
PD4-1641609177,
PD4-822226531
The following error message is logged during an MSM failover on a BlackDiamond
20800 series switch:
<Warn> Function pointer is not supported. Caller: 0x42e6b8 Parm1:
0x107f24a0 Parm2: 0x108490a0
PD4-1409776545 When receiving a specific CFM packet, the switch displays the following error message:
Error: can't read xmlData.
Summit Family Switches
PD4-1634882151,
PD4-1634368131
When multiple FDB entries share a common set of egress ports spread across units,
traffic to certain MAC addresses may not be forwarded on all the ports (ESP ports on
alternate units).
PD4-1629547723,
PD4-1095983624
When applying an ACL on a Summit X450a switch, the following error is generated:
Error: ACL install operation failed - slice hardware full for
port.
PD4-1621116096,
PD4-1229411629
No error message is generated on a Summit X450 switch when applying a secondary
ethertype (not 8100) on a tagged vMAN or VLAN port.
SummitStack
PD4-1585599578,
PD4-1049718893
On a SummitStack, WAN-PHY error counters are not correct on the backup or standby
node.
PD4-1584840419,
PD4-1236337241
UPM becomes active before configuration check pointing is complete, causing the UPM
script to fail.
BGP
PD4-1449255294 A switch sends a BGP withdrawn message even though it has an alternate route.
OSPFv3
PD4-1386631981,
PD4-1313201611
OSPFv3 process crashes when an ASBR that was reachable through multiple areas
goes down.
SNMP
PD4-1491778548,
PD4-1578876722
snmpSubagent process crashes with signal 11 when creating a row in the pingCtlTable
with a pingCtlTestName length greater than 32 bytes.
Workaround: Use pingCtlTestName with a length less than 32 bytes.
Spanning Tree Protocol
PD4-1637570461,
PD4-1598240578
STP crashes when making topology changes to a domain name containing more than 29
characters.
Workaround: Use STP domain names that are less than 30 characters.
Table 51: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description